The heart of the HFI - the detectors - are bolometers, solid-state devices in which the
 
The heart of the HFI - the detectors - are bolometers, solid-state devices in which the
 
incoming radiation dissipates its energy as heat that increases the temperature of a
 
incoming radiation dissipates its energy as heat that increases the temperature of a
thermometer. The instrument Flight Model total number of bolometers is 52, split into 6
+
thermometer. The instrument Flight Model total number of bolometers is 52, split into six
 
channels at central frequencies of 100, 143, 217, 353, 545, and 857 GHz.  
 
channels at central frequencies of 100, 143, 217, 353, 545, and 857 GHz.  
Two extra bolometers not optically coupled to the telescope are added to the focal plane
+
Two extra bolometers, not optically coupled to the telescope, are added to the focal plane
to monitor thermal noise (Dark Bolometers).  
+
to monitor thermal noise (dark bolometers).  
  
Thirty two of these bolometers are polarization sensitive allowing a map of the CMB polarisation to be built.
+
The bolometers consist of:
 +
* an absorber that transforms the in-coming radiation into heat;
 +
* a semi-conducting NTD thermistor that is thermally linked to the absorber and measures the temperature changes;
 +
* and a weak thermal link to a thermal sink, to which the bolometer is attached.
  
 +
There are two kinds of detector modules: polarization-sensitive bolometers (PSBs) and spider-web bolometers (SWBs).
  
Bolometers consist of (i) an absorber that transforms the in-coming radiation into heat; (ii) a thermometer that is thermally linked to the absorber and measures the temperature changes; and (iii) a weak thermal link to a thermal sink, to which the bolometer is attached.
+
'''Spider-web bolometers''' {{BibCite|Bock1995}}{{BibCite|Mauskopf1997}}
  
 
+
In these bolometers, the absorber consists of a metallic grid deposited on a Si3 N4 substrate in the shape of a spider web.
The thermometers are semi-conducting NTD thermistor bolometers. There are two kinds of detector modules:
 
 
 
* Spider web bolometers or SWBs (Bock et al. 1995; Mauskopf et al. 1997).
 
 
 
<cite>#Bock1995</cite> {{PEarly|4}}
 
<cite>#Mauskopf1997</cite> {{PEarly|4}}
 
 
 
 
 
In these bomometers, the absorber consists of a metallic grid deposited on a Si3 N4 substrate in the shape of a spider web.
 
 
The mesh design and the impedance of the metallic layer are
 
The mesh design and the impedance of the metallic layer are
adjusted to match vacuum impedance and maximize the absorption of millimeter waves, while minimizing the cross section to
+
adjusted to match vacuum impedance and maximize the absorption of millimetre waves, while minimizing the cross-section to
 
particles. The absorber is designed to offer equal impedance to
 
particles. The absorber is designed to offer equal impedance to
any linearly polarised radiation. Nevertheless, the thermometer
+
any linearly polarized radiation. Nevertheless, the thermometer
 
and its electrical leads define a privileged orientation that
 
and its electrical leads define a privileged orientation that
makes the SWBs slightly sensitive to polarisation, as detailed in
+
makes the SWBs slightly sensitive to polarization, as detailed in
<cite>#rosset2010</cite> {{PPreLaunch|13}}. The thermometers are
+
{{PlanckPapers|rosset2010}}. The thermometers are
made of neutron transmuted doped (NTD) germanium (Haller <cite>#Haller1996</cite> {{PEarly|4}}  
+
made of neutron transmutation doped (NTD) germanium {{BibCite|Haller1996}}, chosen to have an impedance of about 10 MΩ at
et al. 1996), chosen to have an impedance of about 10 MΩ at
 
 
their operating temperature.
 
their operating temperature.
  
[[Image:HFI_2_4_1_FPiacentini_bolo1.png|thumb|500px|center|Picture of a Spider Web Bolometer. This a 143 GHz module, The temperature sensor is at the center of the absorbing grid.]]
+
[[Image:HFI_2_4_1_FPiacentini_bolo1.png|thumb|500px|center|Picture of a spider-web bolometer. This a 143 GHz module. The temperature sensor is at the centre of the absorbing grid.]]
  
* Polarization sensitive bolometers or PSBs.
+
'''Polarization-sensitive bolometers'''
The absorber of PSBs is a rectangular grid with metallization in one direction <cite>#Jones2003</cite>. Electrical fields parallel to this direction develop currents and then deposit some energy in the grid, while perpendicular electrical fields propagate through the grid without significant interaction. A second PSB perpendicular to the first one absorbs the other polarisation. Such a PSB pair measures two polarisations of radiation collected by the same horns and filtered by the same devices, which minimises the systematic effects: differences between polarised
+
 
 +
The absorber of PSBs is a rectangular grid with metallization in one direction {{BibCite|Jones2003}}. Electrical fields parallel to this direction develop currents and then deposit some energy in the grid, while perpendicular electrical fields propagate through the grid without significant interaction. A second PSB, perpendicular to the first one, absorbs the other polarization. Such a PSB pair measures two polarizations of radiation collected by the same horns and filtered by the same devices, which minimizes the systematic effects; differences between polarized
 
beams collected by a given horn are typically less than −30 dB of
 
beams collected by a given horn are typically less than −30 dB of
the peak. The differences in the spectral responses of a PSB pair
+
the peak. The differences in the spectral responses of a PSB pair have
 
also proved to be a few percent in the worst case. Each pair
 
also proved to be a few percent in the worst case. Each pair
 
of PSBs sharing the same horn is able to measure the intensity
 
of PSBs sharing the same horn is able to measure the intensity
Stokes parameter and the Q parameter associated with its local
+
Stokes parameter and the <I>Q</I> parameter associated with its local
frame. An associated pair of PSBs rotated by 45◦ scans exactly
+
frame. An associated pair of PSBs rotated by 45&deg; scans exactly
 
the same line (if the geometrical alignment is perfect), providing
 
the same line (if the geometrical alignment is perfect), providing
the U Stokes parameter.
+
the <I>U</I> Stokes parameter.
  
[[Image:HFI_2_4_1_FPiacentini_bolo2.png|thumb|500px|center|Picture of a Polarization Sensitive Bolometer. This is a 217 GHz module, The temperature sensor is located at an edge of the absorbing grid.]]
+
[[Image:HFI_2_4_1_FPiacentini_bolo2.png|thumb|500px|center|Picture of a polarization-sensitive bolometer. This is a 217 GHz module. The temperature sensor is located at one edge of the absorbing grid.]]
  
The detectors operate at a temperature close to 100 mK, while the filters are distributed on the 100 mK, 1.6 K,
+
The detectors operate at a temperature close to 100 mK, while the filters are distributed on the 100-mK, 1.6-K,
and 4 K stages in such a way that the heat load on the coldest stages is minimized to
+
and 4-K stages, in such a way that the heat load on the coldest stages is minimized, to
 
limit the heat load on the detectors and to decrease
 
limit the heat load on the detectors and to decrease
the heat lift requirement and thus enhance the mission lifetime. The self-emission of the 4K stage is minimised to limit the photon noise contribution on the detectors from the instrument.
+
the heat lift requirement and thus enhance the mission lifetime. The self-emission of the 4-K stage is minimized to limit the photon noise contribution on the detectors from the instrument.
The HFI Focal Plane Unit accommodates sub-millimiter absorbing
+
The HFI Focal Plane Unit accommodates sub-millimitre absorbing
 
material in order to decrease the scattering inside it.
 
material in order to decrease the scattering inside it.
  
Line 65: Line 60:
 
quality is good enough for the high frequencies. The curvature of
 
quality is good enough for the high frequencies. The curvature of
 
rows compensates for the distortion of images by the telescope.
 
rows compensates for the distortion of images by the telescope.
A pair of identical SWB will scan the same circle on the sky to
+
A pair of identical SWBs will scan the same circle on the sky to
 
provide redundancy. Similar horns feeding PSBs are
 
provide redundancy. Similar horns feeding PSBs are
also aligned so that two PSBs rotated by 45◦ with respect to each other scan the same line. This will provide the Q and U Stokes parameters with minimal correction for the pointing (Rosset et al. 2010). Residual systematics will come from the differences between the beam shapes of the two horns. In all
+
also aligned so that two PSBs rotated by 45&deg; with respect to each other scan the same line. This will provide the <I>Q</I> and <I>U</I> Stokes parameters with minimal correction for the pointing {{PlanckPapers|rosset2010}}). Residual systematics will come from the differences between the beam shapes of the two horns. In all cases, except for the 100 GHz horns, a measurement is also done
cases except for the 100 GHz horns, a measurement is also done
+
by a pair of similar channels shifted by 1.25 arcminutes in the cross-scan direction, to ensure adequate sampling. The focal plane layout is reported in the figures.  
by a pair of similar channels shifted by 1.25 arcminutes in the cross-scan direction, to ensure adequate sampling. In the figures focal plane layout is reported.  
 
  
[[Image:HFI_2_4_1_FPiacentini_FocalPlaneGeo.png|thumb|500px|center|Focal plane layout as seen from outside the celestial sphere. In this case PSB orientations are indicated. Red rod is for "a" elements of PSBs, blue rod is for "b" elements. The scan direction is from left to right.]]
+
[[Image:HFI_2_4_1_FPiacentini_FocalPlaneGeo.png|thumb|500px|center|Focal plane layout as seen from outside the celestial sphere. PSB orientations are indicated, with a red rod for the "a" elements and a blue rod for the "b" elements. The scan direction is from left to right.]]
  
 
==Readout==
 
==Readout==
  
The AC bias readout electronics of the HFI instrument (Gaertner et al. 1997) includes the following features  
+
The AC bias readout electronics of the HFI instrument {{BibCite|Gaertner1997}} includes the following features:
 
* the cold load resistors were replaced by capacitors because they have no Johnson noise;
 
* the cold load resistors were replaced by capacitors because they have no Johnson noise;
* the detectors are biased by applying a triangular voltage to the load capacitors which produces a square current (Ibias) in the capacitors, and a square voltage (T bias) that compensates for the stray capacitance of the wiring (producing a nearly square bias current into the bolometer;
+
* the detectors are biased by applying a triangular voltage to the load capacitors, which produces a square current (I-bias) in the capacitors, and a square voltage (T-bias) that compensates for the stray capacitance of the wiring (producing a nearly square bias current into the bolometer);
* a square offset com-pensation signal is subtracted to the bolometric signal to minimise the amplitude of the signal that has to be amplified and digitized;  
+
* a square offset compensation signal is subtracted from the bolometric signal to minimize the amplitude of the signal that has to be amplified and digitized;  
* the electronic scheme is symmetrical and uses a differential amplification scheme to optimize the immunity to electromagnetic interferences;  
+
* the electronic scheme is symmetrical and uses a differential amplification scheme to optimize the immunity to electromagnetic interference;  
* and finally every parameter of the REU can be set by commands, which is made possible by using digital-to-analog and analog-to-digital converters extensively.
+
* and finally every parameter of the REU can be set by commands, which is made possible by extensively using digital-to-analogue and analogue-to-digital converters.
  
The readout electronics consists of 72 channels designed to perform low noise measurements of the impedance of 52 bolometers, two blind bolometers, 16 accurate low-temperature thermometers, all in the 10 MΩ range, one resistor of 10 MΩ and one capacitor of 100 pF. The semiconductor bolometers and thermometers of Planck-HFI operate at cryogenic temperature around 100 mK on the focal plane, with impedance of about 10 MΩ when biased at the optimal current. The readout electronics on the contrary has to operate at “room” temperature (300 K). The distance between the two extremities of the readout chain is about 10 m and could bring about an extreme susceptibility to electromagnetic interference. The readout electronic chain was split into three boxes. These are the JFET box, located on the 50 K stage of the satellite at 2.2 m from the focal plane, the pre-amplifier unit (PAU), located 1.8 m further at 300 K, and the REU, located on the opposite side of the satellite, 5 m away. Each of the three boxes (JFET, PAU and REU) consists of 12 belts of six channels. The first nine belts are dedicated to the bolometers, and the three last ones to the accurate thermometers, the resistor and the capacitor.  
+
The readout electronics consists of 72 channels designed to perform low noise measurements of the impedance of 52 bolometers, two blind bolometers, and 16 accurate low-temperature thermometers, all in the 10 MΩ range, together with one resistor of 10 MΩ and one capacitor of 100 pF. The semiconductor bolometers and thermometers of Planck-HFI operate at cryogenic temperatures around 100 mK on the focal plane, with impedance of about 10 MΩ when biased at the optimal current. The readout electronics, on the other hand, has to operate at “room” temperature (300 K). The distance between the two extremities of the readout chain is about 10 m and this could bring about an extreme susceptibility to electromagnetic interference. The readout electronics chain was therefore split into three boxes. These are the JFET box, located on the 50-K stage of the satellite at 2.2 m from the focal plane, the pre-amplifier unit (PAU), located 1.8 m further at 300 K, and the REU, located on the opposite side of the satellite, 5 m away. Each of the three boxes (JFET, PAU and REU) consists of 12 belts of six channels. The first nine belts are dedicated to the bolometers, and the three last ones to the accurate thermometers, the resistor, and the capacitor.  
  
[[Image:HFI_2_4_1_FPiacentini_HFIreadout.png|thumb|500px|center|Principles of readout electronics. The three modules of the chain are shown: JFET box, Pre-Amplifier Unit (PAU) and Readout Electronic Unit (REU)]]
+
[[Image:HFI_2_4_1_FPiacentini_HFIreadout.png|thumb|500px|center|Principles of readout electronics. The three modules of the chain are shown: JFET box; Pre-Amplifier Unit (PAU); and Readout Electronic Unit (REU)]]
  
 
[[Image:HFI_2_4_1_FPiacentini_table2.jpeg|thumb|500px|center|Organization of the HFI readout. Each row represents a belt. Each belt has six channels.]]
 
[[Image:HFI_2_4_1_FPiacentini_table2.jpeg|thumb|500px|center|Organization of the HFI readout. Each row represents a belt. Each belt has six channels.]]
Line 90: Line 84:
 
==Principles of the readout electronics ==
 
==Principles of the readout electronics ==
  
The bolometer is biased by a square wave AC current obtained by the differentiation of a triangular voltage through a load capacitance, in a completely differential architecture. The presence of the stray capacitance due to losses of charge in the wiring requires a correction of the shape of the square bias current by a transient voltage. Thus the bias voltage generation is controlled by the two parameters I-bias and T-bias that express the amplitude of the triangular and transient voltage. The compensation voltage added to the bolometric signal to optimize the dynamic of the chain is controlled by the V-bal parameter.
+
The bolometer is biased by a square wave AC current obtained by the differentiation of a triangular voltage through a load capacitance, in a completely differential architecture. The presence of stray capacitance due to losses of charge in the wiring requires a correction of the shape of the square bias current by a transient voltage. Thus the bias voltage generation is controlled by the two parameters I-bias and T-bias that express the amplitude of the triangular and transient voltage. The compensation voltage added to the bolometric signal to optimize the dynamics of the chain is controlled by the V-bal parameter.
  
 
The following parameters of the Readout Unit can be set to optimize the detector performance:
 
The following parameters of the Readout Unit can be set to optimize the detector performance:
* fmod, the modulation frequency of the square bias current, was set to 90.18685,
+
* fmod, the modulation frequency of the square bias current, which was set to 90.18685;
* Nsample, which defines the number of samples per half period of modulated signal was set to 40.
+
* Nsample, which defines the number of samples per half period of modulated, which signal was set to 40.
  
 
Each channel has its own settings for the following parameters:
 
Each channel has its own settings for the following parameters:
* I-bias, amplitude of the triangular bias voltage,
+
* I-bias, the amplitude of the triangular bias voltage;
* T-bias, amplitude of the transient bias voltage,
+
* T-bias, the amplitude of the transient bias voltage;
* V-bal, amplitude of the square compensation voltage,
+
* V-bal, the amplitude of the square compensation voltage;
* G-amp, value of the programmable gain of the REU [1/3, 1, 3, 7.6],
+
* G-amp, the value of the programmable gain of the REU [1/3, 1, 3, 7.6];
* N-blank, number of blanked samples at the beginning of halfperiod not taken into account during integration of the signal,
+
* N-blank, the number of blanked samples at the beginning of each half period not taken into account during integration of the signal;
* S-phase, phase shift when computing the integrated signal.
+
* S-phase, the phase shift when computing the integrated signal.
  
 
All these parameters influence the effective response of the
 
All these parameters influence the effective response of the
Line 109: Line 103:
 
verification phase following the launch of
 
verification phase following the launch of
 
Planck. The scientific signal is provided by the integral of the
 
Planck. The scientific signal is provided by the integral of the
signal on each half-period, between limits fixed by the S-phase
+
signal over each half-period, between limits fixed by the S-phase
 
and N-blank parameters.
 
and N-blank parameters.
  
Line 115: Line 109:
 
The interaction of modulated readout electronics with semiconductor
 
The interaction of modulated readout electronics with semiconductor
 
bolometers is rather different from that of a classical
 
bolometers is rather different from that of a classical
DC bias readout <cite>#Jones1953</cite>. The differences were seen during
+
DC bias readout {{BibCite|Jones1953}}. The differences were seen during
 
the calibration of the HFI, although the readout electronics
 
the calibration of the HFI, although the readout electronics
 
was designed to mimic the operation
 
was designed to mimic the operation
of a DC biased bolometric system as far as possible. With the
+
of a DC-biased bolometric system as far as possible. With the
 
AC readout the maximum of responsivity is lower and is obtained
 
AC readout the maximum of responsivity is lower and is obtained
 
for higher bias current in the bolometer with respect to the DC model.
 
for higher bias current in the bolometer with respect to the DC model.
 
This is caused by the stray capacitance in the
 
This is caused by the stray capacitance in the
wiring which has negligible effects for a DC bias and a major
+
wiring, which has negligible effects for a DC bias and a major
 
effect for an AC bias. In our case, a stray capacitance of 150 pF
 
effect for an AC bias. In our case, a stray capacitance of 150 pF
induces increases of NEP ranging from 4% (857 GHz bolometers)  
+
induces increases of NEP, ranging from 4% (857 GHz bolometers)  
to 10% (100 GHz bolometers) and also affects the HFI time
+
to 10% (100 GHz bolometers), and also affects the HFI time
response. Details of the effect of the HFI AC bias system into
+
response. Details of the effect of the HFI AC bias system on
 
the time response of the detectors are discussed in the  
 
the time response of the detectors are discussed in the  
 
[[HFI_detection_chain#Time_response| time response section]].
 
[[HFI_detection_chain#Time_response| time response section]].
Line 132: Line 126:
 
== JFETs==
 
== JFETs==
  
Given the high impedance of the bolometers and the length of the connecting cables, it is  essential that the impedance of the signal is lowered as close as possible to the detectors. In our system this is accomplished by means of JFET source followers, located in boxes connected to the 50 K stage.  
+
Given the high impedance of the bolometers and the length of the connecting cables, it is  essential that the impedance of the signal is lowered as close as possible to that of the detectors. In our system this is accomplished by means of JFET source followers, located in boxes connected to the 50-K stage {{BibCite|Brienza2006}}. There are two JFETs per channel, since the readout is fully differential, and they provide a current amplification of the signal while keeping the voltage amplification very close to unity.
The JFET box has been designed, developed and tested in the Observational Cosmology group in the Physics Department of the University of Rome "La Sapienza" (Brienza D. et al 2006).
 
There are two JFETs per channel, since the readout is fully differential, and they provide a current amplification of the signal while keeping the voltage amplification very close to unity.
 
  
Inside the box, the JFETs are mounted on a thermally insulated plate with an active temperature control to keep them at the optimal temperature of 110 K. With a dissipated power lower than 240 mW, mainly produced by the JFETs and the source resistors, we obtained a noise power spectral density of less than 3 nV Hz1/2 for the frequency range of interest. This increases the total noise of all bolometer channels by less than 5%.
+
Inside the box, the JFETs are mounted on a thermally insulated plate with an active temperature control to keep them at the optimal temperature of 110 K. With a dissipated power lower than 240 mW, mainly produced by the JFETs and the source resistors, we obtained a noise power spectral density of less than 3 nV Hz<sup>1/2</sup> for the frequency range of interest. This increases the total noise of all bolometer channels by less than 5%.
  
 
== Time response ==
 
== Time response ==
  
The HFI bolometers and readout electronics have a finite response-time to changes of the incident optical power modeled as a Fourier domain transfer function (called the LFER4 model). LFER4 has two factors. The first one represents the bolometer thermal response, driven by its heat capacity, the thermal link to the bolometer plate at 100 mK, and by the thermo-electrical feed-back (ref. Catalano et al.) resulting from the heat deposited in the bolometer by the readout electronics. This factor is empirically obtained from the observation of sources. The second factor is simply the time response of the part of the readout electronics that amplifies and digitizes the signal. It is obtained by modelling the electronics with only very few free parameters.
+
The HFI bolometers and readout electronics have a finite response-time to changes of the incident optical power, modelled as a Fourier domain transfer function, consisting of the product of a bolometer thermal response <I>F</I>(&omega;) and an electronics response <I>H'</I>(&omega;):
+
 
The time response of the HFI bolometers and readout electronics is modeled as a Fourier domain transfer function (called the LFER4 model) consisting of the product of a bolometer thermal response <math>F(\omega)</math> and an electronics response <math>H'(\omega)</math>.  
+
<math>\label{LFER4def}TF^{LFER}(\omega) = F(\omega) H'(\omega)</math>.
 +
 
 +
The first part represents the bolometer thermal response, driven by its heat capacity, by the thermal link to the bolometer plate at 100 mK, and by the thermo-electrical feed-back {{BibCite|catalano2010}} resulting from the heat deposited in the bolometer by the readout electronics. This factor is empirically obtained from the observation of sources. The second factor is simply the time response of the part of the readout electronics that amplifies and digitizes the signal. It is obtained by modelling the electronics using only a very few free parameters.
 +
 
 +
Due to Planck's nearly constant scan rate, the time response is degenerate with the optical beam.  However, because of the long timescale effects present in the time response, the  time response is deconvolved from the data in the processing of the HFI data (see [[TOI processing|TOI processing]]).  <I>F</I>(&omega;) is tuned to optimize the "compactness" of the beams reconstructed with the deconvolved signal from planets.
  
<math>\label{LFER4def}TF^{LFER4}(\omega) = F(\omega) H'(\omega)</math>
+
The model developed and applied to the 2013 release data (PR1, see {{PlanckPapers|planck2013-p03c}}) is referred to as the LFER4 model.
  
Due to Planck's nearly constant scan rate, the time response is degenerate with the optical beam. However, because of the long time scale effects present in the time response, the time response is deconvolved from the data in the processing of the HFI data (see [[TOI processing|TOI processing]]).  <math>F(\omega)</math> is tuned to optimize the "compactness" of the beams reconstructed with the deconvolved signal from planets.
+
For the 2015 (PR2) release (see {{PlanckPapers|planck2014-a08}}), as well as for the 2018 (PR3) release, five time constants are used rather than four, and the values of the parameters have been measured from a different combination of data than used previously. The extra low-pass function and the consequent parameter updates are motivated by the discovery of a time delay between the measured CMB dipole and the expected one. In addition, new information comes from the stacking of glitches induced by high energy particles hits. As described in Planck Collaboration X (2014), short glitches are due to direct interaction of particles with the bolometer grid or thermistor. The time response of short events is then representative of the response to photons, and glitches can be stacked to determine time response constants. In summary, the values of the bolometer time transfer function parameters, ai and τi, are measured with the following logic:
 +
* the two fastest time constants, τ1 and τ2, and the associated amplitudes a1 and a2, are unchanged with respect to the previous version, i.e., they are estimated from planet observations;
 +
* the two longest time constants, τ4 and τ5, are estimated from short glitch stacking, together with the a5/a4 ratio;
 +
* τ3, a3, and a4 are fitted from Jupiter scans, keeping τ1, a1, τ2, and a2 fixed, while the value of a5 is set to keep the same ratio a5/a4 as in the glitch data;
 +
* a5 is fitted from the CMB dipole time shift. It should be noted that the same dipole time shift can be obtained with different combinations of a5 and τ5 and for this reason, τ5 is recovered from the short glitches, and only a5 from the dipole time shift.
  
Details about the time response model are to be found in [[HFI_time_response_model | this annex]].
+
Details about the time response models of PR1 and PR2 can be found in [[HFI_time_response_model | this annex]].
  
 
==Data compression==
 
==Data compression==
  
 
The output of the readout electronics unit (REU) consists of one
 
The output of the readout electronics unit (REU) consists of one
value for each of the 72 science channels (bolometers and thermometers) for each modulation half-period. This number, <math>S_{REU}</math>, is the sum
+
value for each of the 72 science channels (bolometers and thermometers) for each modulation half-period. This number, <I>S</I><sub>REU</sub>, is the sum
 
of the 40 16-bit ADC signal values measured within the given
 
of the 40 16-bit ADC signal values measured within the given
 
half-period. The data processor unit (DPU) performs a lossy
 
half-period. The data processor unit (DPU) performs a lossy
quantization of <math>S_{REU}</math>.
+
quantization of <I>S</I><sub>REU</sub>.
  
Details about the data compression scheme, performance of the data compression during the mission, setting the quantization step in flight, impact of the data compression on science are given in [[HFI_data_compression | this annex]].
+
Details about the data compression scheme, performance of the data compression during the mission, setting the quantization step in flight, and the impact of the data compression on science, are given in [[HFI_data_compression | this annex]].
  
 
== References ==
 
== References ==
<biblio force=false>
+
<References />
#[[References]]
+
 
#[[References2]]
+
</biblio>
+
 
  
[[Category:The satellite|0024]]
+
[[Category:HFI design, qualification and performance|003]]

Latest revision as of 21:36, 19 June 2018

Bolometers[edit]

The heart of the HFI - the detectors - are bolometers, solid-state devices in which the incoming radiation dissipates its energy as heat that increases the temperature of a thermometer. The instrument Flight Model total number of bolometers is 52, split into six channels at central frequencies of 100, 143, 217, 353, 545, and 857 GHz. Two extra bolometers, not optically coupled to the telescope, are added to the focal plane to monitor thermal noise (dark bolometers).

The bolometers consist of:

  • an absorber that transforms the in-coming radiation into heat;
  • a semi-conducting NTD thermistor that is thermally linked to the absorber and measures the temperature changes;
  • and a weak thermal link to a thermal sink, to which the bolometer is attached.

There are two kinds of detector modules: polarization-sensitive bolometers (PSBs) and spider-web bolometers (SWBs).

Spider-web bolometers [1][2]

In these bolometers, the absorber consists of a metallic grid deposited on a Si3 N4 substrate in the shape of a spider web. The mesh design and the impedance of the metallic layer are adjusted to match vacuum impedance and maximize the absorption of millimetre waves, while minimizing the cross-section to particles. The absorber is designed to offer equal impedance to any linearly polarized radiation. Nevertheless, the thermometer and its electrical leads define a privileged orientation that makes the SWBs slightly sensitive to polarization, as detailed in Planck-PreLaunch-XIII[3]. The thermometers are made of neutron transmutation doped (NTD) germanium [4], chosen to have an impedance of about 10 MΩ at their operating temperature.

Picture of a spider-web bolometer. This a 143 GHz module. The temperature sensor is at the centre of the absorbing grid.

Polarization-sensitive bolometers

The absorber of PSBs is a rectangular grid with metallization in one direction [5]. Electrical fields parallel to this direction develop currents and then deposit some energy in the grid, while perpendicular electrical fields propagate through the grid without significant interaction. A second PSB, perpendicular to the first one, absorbs the other polarization. Such a PSB pair measures two polarizations of radiation collected by the same horns and filtered by the same devices, which minimizes the systematic effects; differences between polarized beams collected by a given horn are typically less than −30 dB of the peak. The differences in the spectral responses of a PSB pair have also proved to be a few percent in the worst case. Each pair of PSBs sharing the same horn is able to measure the intensity Stokes parameter and the Q parameter associated with its local frame. An associated pair of PSBs rotated by 45° scans exactly the same line (if the geometrical alignment is perfect), providing the U Stokes parameter.

Picture of a polarization-sensitive bolometer. This is a 217 GHz module. The temperature sensor is located at one edge of the absorbing grid.

The detectors operate at a temperature close to 100 mK, while the filters are distributed on the 100-mK, 1.6-K, and 4-K stages, in such a way that the heat load on the coldest stages is minimized, to limit the heat load on the detectors and to decrease the heat lift requirement and thus enhance the mission lifetime. The self-emission of the 4-K stage is minimized to limit the photon noise contribution on the detectors from the instrument. The HFI Focal Plane Unit accommodates sub-millimitre absorbing material in order to decrease the scattering inside it.


HFI 2 4 1 FPiacentini table1.png

Focal plane layout[edit]

The layout of the detectors in the focal plane is defined in relation to the scanning strategy. The HFI horns are positioned at the centre of the focal plane, where the optical quality is good enough for the high frequencies. The curvature of rows compensates for the distortion of images by the telescope. A pair of identical SWBs will scan the same circle on the sky to provide redundancy. Similar horns feeding PSBs are also aligned so that two PSBs rotated by 45° with respect to each other scan the same line. This will provide the Q and U Stokes parameters with minimal correction for the pointing Planck-PreLaunch-XIII[3]). Residual systematics will come from the differences between the beam shapes of the two horns. In all cases, except for the 100 GHz horns, a measurement is also done by a pair of similar channels shifted by 1.25 arcminutes in the cross-scan direction, to ensure adequate sampling. The focal plane layout is reported in the figures.

Focal plane layout as seen from outside the celestial sphere. PSB orientations are indicated, with a red rod for the "a" elements and a blue rod for the "b" elements. The scan direction is from left to right.

Readout[edit]

The AC bias readout electronics of the HFI instrument [6] includes the following features:

  • the cold load resistors were replaced by capacitors because they have no Johnson noise;
  • the detectors are biased by applying a triangular voltage to the load capacitors, which produces a square current (I-bias) in the capacitors, and a square voltage (T-bias) that compensates for the stray capacitance of the wiring (producing a nearly square bias current into the bolometer);
  • a square offset compensation signal is subtracted from the bolometric signal to minimize the amplitude of the signal that has to be amplified and digitized;
  • the electronic scheme is symmetrical and uses a differential amplification scheme to optimize the immunity to electromagnetic interference;
  • and finally every parameter of the REU can be set by commands, which is made possible by extensively using digital-to-analogue and analogue-to-digital converters.

The readout electronics consists of 72 channels designed to perform low noise measurements of the impedance of 52 bolometers, two blind bolometers, and 16 accurate low-temperature thermometers, all in the 10 MΩ range, together with one resistor of 10 MΩ and one capacitor of 100 pF. The semiconductor bolometers and thermometers of Planck-HFI operate at cryogenic temperatures around 100 mK on the focal plane, with impedance of about 10 MΩ when biased at the optimal current. The readout electronics, on the other hand, has to operate at “room” temperature (300 K). The distance between the two extremities of the readout chain is about 10 m and this could bring about an extreme susceptibility to electromagnetic interference. The readout electronics chain was therefore split into three boxes. These are the JFET box, located on the 50-K stage of the satellite at 2.2 m from the focal plane, the pre-amplifier unit (PAU), located 1.8 m further at 300 K, and the REU, located on the opposite side of the satellite, 5 m away. Each of the three boxes (JFET, PAU and REU) consists of 12 belts of six channels. The first nine belts are dedicated to the bolometers, and the three last ones to the accurate thermometers, the resistor, and the capacitor.

Principles of readout electronics. The three modules of the chain are shown: JFET box; Pre-Amplifier Unit (PAU); and Readout Electronic Unit (REU)
Organization of the HFI readout. Each row represents a belt. Each belt has six channels.

Principles of the readout electronics[edit]

The bolometer is biased by a square wave AC current obtained by the differentiation of a triangular voltage through a load capacitance, in a completely differential architecture. The presence of stray capacitance due to losses of charge in the wiring requires a correction of the shape of the square bias current by a transient voltage. Thus the bias voltage generation is controlled by the two parameters I-bias and T-bias that express the amplitude of the triangular and transient voltage. The compensation voltage added to the bolometric signal to optimize the dynamics of the chain is controlled by the V-bal parameter.

The following parameters of the Readout Unit can be set to optimize the detector performance:

  • fmod, the modulation frequency of the square bias current, which was set to 90.18685;
  • Nsample, which defines the number of samples per half period of modulated, which signal was set to 40.

Each channel has its own settings for the following parameters:

  • I-bias, the amplitude of the triangular bias voltage;
  • T-bias, the amplitude of the transient bias voltage;
  • V-bal, the amplitude of the square compensation voltage;
  • G-amp, the value of the programmable gain of the REU [1/3, 1, 3, 7.6];
  • N-blank, the number of blanked samples at the beginning of each half period not taken into account during integration of the signal;
  • S-phase, the phase shift when computing the integrated signal.

All these parameters influence the effective response of the detection chains, and were optimized during the calibration campaigns and confirmed during the calibration and performance verification phase following the launch of Planck. The scientific signal is provided by the integral of the signal over each half-period, between limits fixed by the S-phase and N-blank parameters.


The interaction of modulated readout electronics with semiconductor bolometers is rather different from that of a classical DC bias readout [7]. The differences were seen during the calibration of the HFI, although the readout electronics was designed to mimic the operation of a DC-biased bolometric system as far as possible. With the AC readout the maximum of responsivity is lower and is obtained for higher bias current in the bolometer with respect to the DC model. This is caused by the stray capacitance in the wiring, which has negligible effects for a DC bias and a major effect for an AC bias. In our case, a stray capacitance of 150 pF induces increases of NEP, ranging from 4% (857 GHz bolometers) to 10% (100 GHz bolometers), and also affects the HFI time response. Details of the effect of the HFI AC bias system on the time response of the detectors are discussed in the time response section.

JFETs[edit]

Given the high impedance of the bolometers and the length of the connecting cables, it is essential that the impedance of the signal is lowered as close as possible to that of the detectors. In our system this is accomplished by means of JFET source followers, located in boxes connected to the 50-K stage [8]. There are two JFETs per channel, since the readout is fully differential, and they provide a current amplification of the signal while keeping the voltage amplification very close to unity.

Inside the box, the JFETs are mounted on a thermally insulated plate with an active temperature control to keep them at the optimal temperature of 110 K. With a dissipated power lower than 240 mW, mainly produced by the JFETs and the source resistors, we obtained a noise power spectral density of less than 3 nV Hz1/2 for the frequency range of interest. This increases the total noise of all bolometer channels by less than 5%.

Time response[edit]

The HFI bolometers and readout electronics have a finite response-time to changes of the incident optical power, modelled as a Fourier domain transfer function, consisting of the product of a bolometer thermal response F(ω) and an electronics response H'(ω):

[math]\label{LFER4def}TF^{LFER}(\omega) = F(\omega) H'(\omega)[/math].

The first part represents the bolometer thermal response, driven by its heat capacity, by the thermal link to the bolometer plate at 100 mK, and by the thermo-electrical feed-back [9] resulting from the heat deposited in the bolometer by the readout electronics. This factor is empirically obtained from the observation of sources. The second factor is simply the time response of the part of the readout electronics that amplifies and digitizes the signal. It is obtained by modelling the electronics using only a very few free parameters.

Due to Planck's nearly constant scan rate, the time response is degenerate with the optical beam. However, because of the long timescale effects present in the time response, the time response is deconvolved from the data in the processing of the HFI data (see TOI processing). F(ω) is tuned to optimize the "compactness" of the beams reconstructed with the deconvolved signal from planets.

The model developed and applied to the 2013 release data (PR1, see Planck-2013-VII[10]) is referred to as the LFER4 model.

For the 2015 (PR2) release (see Planck-2015-A07[11]), as well as for the 2018 (PR3) release, five time constants are used rather than four, and the values of the parameters have been measured from a different combination of data than used previously. The extra low-pass function and the consequent parameter updates are motivated by the discovery of a time delay between the measured CMB dipole and the expected one. In addition, new information comes from the stacking of glitches induced by high energy particles hits. As described in Planck Collaboration X (2014), short glitches are due to direct interaction of particles with the bolometer grid or thermistor. The time response of short events is then representative of the response to photons, and glitches can be stacked to determine time response constants. In summary, the values of the bolometer time transfer function parameters, ai and τi, are measured with the following logic:

  • the two fastest time constants, τ1 and τ2, and the associated amplitudes a1 and a2, are unchanged with respect to the previous version, i.e., they are estimated from planet observations;
  • the two longest time constants, τ4 and τ5, are estimated from short glitch stacking, together with the a5/a4 ratio;
  • τ3, a3, and a4 are fitted from Jupiter scans, keeping τ1, a1, τ2, and a2 fixed, while the value of a5 is set to keep the same ratio a5/a4 as in the glitch data;
  • a5 is fitted from the CMB dipole time shift. It should be noted that the same dipole time shift can be obtained with different combinations of a5 and τ5 and for this reason, τ5 is recovered from the short glitches, and only a5 from the dipole time shift.

Details about the time response models of PR1 and PR2 can be found in this annex.

Data compression[edit]

The output of the readout electronics unit (REU) consists of one value for each of the 72 science channels (bolometers and thermometers) for each modulation half-period. This number, SREU, is the sum of the 40 16-bit ADC signal values measured within the given half-period. The data processor unit (DPU) performs a lossy quantization of SREU.

Details about the data compression scheme, performance of the data compression during the mission, setting the quantization step in flight, and the impact of the data compression on science, are given in this annex.

References[edit]

  1. A Novel Bolometer for Infrared and Millimeter-Wave Astrophysics, J. J. Bock, D. Chen, P. D. Mauskopf, A. E. Lange, Space Science Reviews, 74, 229-235, (1995).
  2. Composite infrared bolometers with Si 3 N 4 micromesh absorbers, P. D. Mauskopf, J. J. Bock, H. del Castillo, W. L. Holzapfel, A. E. Lange, Appl. Opt, 36, 765-771, (1997).
  3. 3.03.1 Planck pre-launch status: High Frequency Instrument polarization calibration, C. Rosset, M. Tristram, N. Ponthieu, et al. , A&A, 520, A13+, (2010).
  4. Neutron Transmutation Depot (NTD) Germanium Thermistors for Submillimetre Bolometer Applications, E. E. Haller, K. M. Itoh, J. W. Beeman, in Submillimetre and Far-Infrared Space Instrumentation E. J. Rolfe, G. Pilbratt (Ed.), ESA Special Publication, 388, 115-+, (1996).
  5. A Polarization Sensitive Bolometric Receiver for Observations of the Cosmic Microwave Background, W. C. Jones, R. Bhatia, J. J. Bock, A. E. Lange, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series T. G. Phillips, J. Zmuidzinas (Ed.), Presented at the Society of Photo-Optical Instrumentation Engineers (SPIE) Conference, 4855, 227-238, (2003).
  6. A new readout system for bolometers with improved low frequency stability, S. Gaertner, A. Benoît, J.-M. Lamarre, M. Giard, J.-L. Bret, J.-P. Chabaud, F.-X. Desert, J.-P. Faure, G. Jegoudez, J. Lande, J. Leblanc, J.-P. Lepeltier, J. Narbonne, M. Piat, R. Pons, G. Serra, G. Simiand, A&As, 126, 151-160, (1997).
  7. The general theory of bolometer performance, R. C. Jones, Journal of the Optical Society of America (1917-1983), 43, 1-+, (1953).
  8. Cryogenic pre-amplifiers for high resistance bolometers, D., de Angelis, L., de Bernardis, P., et al., Brienza, in Seventh International Workshop on Low Temperature Electronics WOLTE-7, ESA-WPP-264283, (2006).
  9. Analytical approach to optimizing alternating current biasing of bolometers, A. Catalano, A. Coulais, J.-M. Lamarre, Appl. Opt., 49, 5938--5946, (2010).
  10. Planck 2013 results. VII. HFI time response and beams, Planck Collaboration, 2014, A&A, 571, A7.
  11. Planck 2015 results. VII. High Frequency Instrument data processing: Time-ordered information and beam processing, Planck Collaboration, 2016, A&A, 594, A7.