Search results

Jump to: navigation, search
  • There are 54 files; 6 HFI bands x 5 surveys & 3 LFI bands x 8 surveys. They are named: The files themselves are in FITS format, and gzipped, with data in the first extension
    2 KB (375 words) - 02:30, 22 February 2017
  • ...inner wall of the mainframe (the wall facing the HFI instrument) from the HFI side. 44 and 30 GHz FEMs are inserted into the main frame from the WG side ...bout 0.1° ; the corresponding precision is approximately 1° in the HFI polarimeters. The temperature stability requirement values are also given i
    60 KB (9,314 words) - 08:48, 2 January 2015
  • == HFI maps power spectra == ...the data, and therefore determine the best cosmological models fitting the data. Several examples of such high-<math>\ell</math> likelihoods are described,
    25 KB (3,718 words) - 15:37, 18 July 2014
  • ...ery stable conditions during the whole mission, and practically all of the data were correctly recorded. The extreme sensitivity provided by the 100 mK bolometers and the HFI architecture provided a new view of the submillimetre and millimetre sky, w
    5 KB (674 words) - 14:36, 2 July 2018
  • ...nckPapers|planck2016-l04}} (and references therein), give details of these processing steps. Four separate component-separation methods are used, which we now d ...al observations from WMAP and Haslam. For the reduction of the Planck 2018 data set, which includes only full-frequency maps, a simpler model is employed,
    16 KB (2,572 words) - 10:22, 10 July 2018
  • The CMB data are in thermodynamic temperature units (uK_cmb), and the residuals are in t ...applied to Planck simulations Leach et al., 2008 and to WMAP polarisation data Fernandez-cobos et al., 2012. In the cleaning process, no assumptions about
    7 KB (1,103 words) - 18:38, 1 March 2013
  • == HFI Unit Conversion Tables == ...nstances), including uncertainty estimates based on the uncertainty of the HFI detector spectral response. The derivation of the unit conversion coeffici
    77 KB (2,387 words) - 14:23, 24 November 2017
  • ...is delivered as a tarfile and contains a detailed instruction manual. The data and software file requirements are provided below along with basic use inst ...>: a routine to get the desired detector level spectral transmission data (HFI) and output in a structure format used by the other routines.
    29 KB (4,821 words) - 09:34, 10 July 2018
  • This is a list of all annexes for the HFI instrument section. ** [[HFI_optical_efficiency|HFI spectral response optical efficiency measurements]];
    812 bytes (97 words) - 06:52, 10 December 2014
  • ...truction of the spatial response for the Planck High Frequency Instrument (HFI) is informed by observation of planets. Furthermore, observations of Uranus ...d time response function, and the software low-pass filter, applied to the data. The "effective beam" represents the averaging of the signal due to the sca
    53 KB (8,689 words) - 15:07, 2 July 2018
  • ...it is obtained, followed by a description of the FITS file containing the data and associated information. ...his data release, to fully characterize the large-scale residuals from the data or from simulations. Therefore all results published by the Planck Collabor
    73 KB (10,660 words) - 08:15, 21 August 2016
  • * 2013-05-21, Jaffe, [[Detector_pointing|HFI Detector Pointing]]: Changes from Reijo Keskitalo and others. <span style=" ...processing]], [[Spectral response]], [[HFI-Validation]], [[Summary of HFI data characteristics]], [[Compact Source catalogues]], [[The RIMO]], [[Effective
    12 KB (1,788 words) - 08:42, 25 September 2014
  • ...detectors are known exactly a priori, we must calibrate them using flight data. ...ar as our ability to predict their effects is concerned. In this delivery HFI used a model (described below) to follow the pointing drift continuously,
    5 KB (746 words) - 13:21, 12 January 2018
  • ##[[HFI design, qualification, and performance|HFI design, qualification, and performance]] #[[Data processing]]
    5 KB (581 words) - 09:33, 31 March 2014
  • ...04-15: Moneti: Added info on HFI Planet TOIs in [[Timelines | Time ordered data]] (APPROVED, IN PLA, ES PAGE PUBLIC) ...ott: finished fixing style in [[Map-making]], [[Spectral_response]], and [[HFI-Validation]]
    6 KB (842 words) - 00:29, 7 April 2018
  • Instrument (LFI), and a SAMBA-like High Frequency Instrument (HFI), instruments, as well as the ensuing data analysis
    15 KB (2,330 words) - 12:43, 17 July 2018
  • ...Temperature beam window functions for polarized and unpolarized detectors (HFI PSB and SWBs) ==== ...the HEALPix resolution parameter <i>N</i><sub>side</sub> (=2048 for Planck HFI maps).
    11 KB (1,796 words) - 11:47, 22 June 2021
  • ...diation from the sky onto a focal plane shared by detectors of the LFI and HFI, operating at 20K and 0.1K, respectively; a telescope baffle that simultane |'''On-board data storage capacity'''
    30 KB (4,647 words) - 09:23, 10 July 2018
  • ##[[HFI design, qualification, and performance|HFI design, qualification, and performance]] ##[[Data flow overview|Data flow overview]] (<span style="color:red">Leonardi</span>,<span style="color
    6 KB (744 words) - 09:45, 31 March 2014
  • The heart of the HFI - the detectors - are bolometers, solid-state devices in which the The HFI Focal Plane Unit accommodates sub-millimiter absorbing
    13 KB (2,128 words) - 15:29, 4 June 2014

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)