Difference between revisions of "Talk:Product Table for PLAv2"
(→Product categories) |
(→Detector set maps) |
||
(11 intermediate revisions by 2 users not shown) | |||
Line 5: | Line 5: | ||
=====All detectors===== | =====All detectors===== | ||
=====Detector maps===== | =====Detector maps===== | ||
+ | [MFB]: halfring is wrong, we'd agreed on using the literal ringhalf. | ||
+ | |||
+ | [LM]: Corrected. | ||
+ | |||
=====Detector set maps===== | =====Detector set maps===== | ||
+ | [MFB]: in the ICD the detector set maps are identified by "ds", not "DetSet". Should we change this in the ICD? | ||
+ | |||
+ | [LM]: Lets stick to ds | ||
+ | |||
=====Low resolution maps===== | =====Low resolution maps===== | ||
=====Correction maps===== | =====Correction maps===== | ||
+ | ====Component maps==== | ||
+ | [MFB]: Sat propose a change in the naming convention for CMB maps to fit the new layout requirements (separate CMB and foreground maps). | ||
+ | |||
+ | <origin>_CMB_<resolution>-<method>_<NSide>_<Rn.mm>_<coverage>.fits | ||
+ | |||
+ | [LM]: This is fine as long as <resolution> is representation | ||
+ | |||
+ | <origin>_CMB_<representation>-<method>_<NSide>_<Rn.mm>_<coverage>.fits | ||
+ | |||
+ | I changed the names accordingly | ||
+ | |||
+ | |||
+ | ---- | ||
+ | [MFB]: in the last release it was agreed to use lfreqf'''g'''r instead lfreqf'''o'''r to identify the low-frequency Galactic emission. | ||
+ | |||
+ | [LM]: Corrected. | ||
+ | |||
+ | ====Masks==== | ||
+ | [MFB]: the naming convention for Masks should be improved to get a better categorization of Masks maps: | ||
+ | |||
+ | <origin>_Mask_<Mask-Type>-<ExtraIdentifier>_<NSide>_<Rn.mm>_<coverage>.fits | ||
+ | |||
+ | e.g. | ||
+ | LFI_Mask_PointSrc-030_2048_R2.xx.fits (Mask, category PointSrc) | ||
+ | COM_Mask_Gal-06_2048_R2.xx.fits (category Gal) | ||
+ | |||
+ | [LM]: I changed the names in the tables accordingly. | ||
+ | |||
===Angular power spectra=== | ===Angular power spectra=== | ||
===Characterization=== | ===Characterization=== | ||
===Catalogues=== | ===Catalogues=== | ||
− | === | + | ===Other products=== |
Latest revision as of 11:36, 12 June 2014
Contents
Product categories[edit]
Time Series[edit]
Maps[edit]
Sky Maps[edit]
All detectors[edit]
Detector maps[edit]
[MFB]: halfring is wrong, we'd agreed on using the literal ringhalf.
[LM]: Corrected.
Detector set maps[edit]
[MFB]: in the ICD the detector set maps are identified by "ds", not "DetSet". Should we change this in the ICD?
[LM]: Lets stick to ds
Low resolution maps[edit]
Correction maps[edit]
Component maps[edit]
[MFB]: Sat propose a change in the naming convention for CMB maps to fit the new layout requirements (separate CMB and foreground maps).
<origin>_CMB_<resolution>-<method>_<NSide>_<Rn.mm>_<coverage>.fits
[LM]: This is fine as long as <resolution> is representation
<origin>_CMB_<representation>-<method>_<NSide>_<Rn.mm>_<coverage>.fits
I changed the names accordingly
[MFB]: in the last release it was agreed to use lfreqfgr instead lfreqfor to identify the low-frequency Galactic emission.
[LM]: Corrected.
Masks[edit]
[MFB]: the naming convention for Masks should be improved to get a better categorization of Masks maps:
<origin>_Mask_<Mask-Type>-<ExtraIdentifier>_<NSide>_<Rn.mm>_<coverage>.fits
e.g. LFI_Mask_PointSrc-030_2048_R2.xx.fits (Mask, category PointSrc) COM_Mask_Gal-06_2048_R2.xx.fits (category Gal)
[LM]: I changed the names in the tables accordingly.
Angular power spectra[edit]
Characterization[edit]
Catalogues[edit]
Other products[edit]
Interface Control Document
Cosmic Microwave background
(Planck) Low Frequency Instrument