== Overview ==
Data validation is a step of paramount importance in the complex process of data analysis and the extraction of the final
+
Data validation is critical at each step of the analysis pipeline.  Much of the LFI data validation is based on null tests. Here we present some examples from the current release, with comments on relevant time scales and sensitivity to various systematics. In the 2018 release in addition we perform many test to verify the differences between this and previous release (see {{PlanckPapers|planck2016-l02}}).
scientific goals of an experiment. The LFI approach to data validation is based upon null-tests approach and here we present
 
the rationale behind envisaged/performed null-tests and the actual results for the present data release. Also we will provide
 
results of the same kind of tests performed on previous release to show the overall improvements in the data quality.
 
  
== Null-tests approach ==
+
== Null tests approach ==
In general null-tests are performed in order to highlight possible issues in the data related to instrumental  
+
Null tests at map level are performed routinely, whenever changes are made to the mapmaking pipeline.  These include differences at survey, year, 2-year, half- mission and half-ring levels, for single detectors, horns, horn pairs and full frequency complements.  Where possible, map differences are generated in <i>I</i>, <i>Q</i> and <i>U</i>.
systematic effect not properly accounted for within the processing pipeline and related to known events of the
+
For this release, we use the Full Focal Plane 10 (FFP10) simulations for comparison. We can use FFP10 noise simulations, identical to the data in terms of sky sampling and with matching time domain noise characteristics, to make statistical arguments about the likelihood of the noise observed in the actual data nulls.
operational conditions (e.g. switch-over of the sorption coolers) or to intrinsic instrument properties coupled with
+
In general null tests are performed to highlight possible issues in the data related to instrumental systematic effecst not properly accounted for within the processing pipeline, or related to known changes in the operational conditions (e.g., switch-over of the sorption coolers), or related to intrinsic instrument properties coupled with the sky signal, such as stray light contamination.
sky signal like stray-light contamination.
+
Such null-tests can be performed by using data on different time scales ranging from 1 minute to 1 year of observations, at different unit levels (radiometer, horn, horn-pair), within frequency and cross-frequency, both in total intensity, and, when applicable, in polarization.
  
Such null-tests are expected to be performed considering data on different time scales ranging from 1-minute to one year
+
=== Sample Null Maps ===
of observations, at different unit level (radiometer, horn, horn-pair, within frequency and cross-frequency both in total
 
intensity and, when applicable, to polarisation.
 
  
This is quite  demanding in terms of all possible combinations. In addition some tools are already
+
[[File:Fig_13.png|thumb|center|900px]]
available and can be properly used for this kind of analysis. However it may be
 
possible that on some specific time-scale, detailed tools have to be developed in order
 
to produce the desired null-test results. In this respect the actual half-ring jack-knives
 
are suitable to track any effects on pointing period times scales. On time-scales between half-ring
 
and survey there are lot of possibilities. It has to be verified if the actual code producing
 
half-ring jack-knives (madam) can handle data producing jack-knives of larger
 
(e.g. 1 hour) times scales.
 
  
It is fundamental that such test have to be performed on DPC data product with clear
+
This figure shows difefrences between 2018 and 1015 frequenncy maps in <i>I</i>, <i>Q</i> and <i>U</i>. Large scale differences between the two set of maps are mainly due to changes in the calibration procedure.
and identified properties (e.g. single $R$, $DV/V$ single fit, etc.) in order to avoid any
 
possible mis-understanding due to usage of non homogeneous data sets.
 
  
Many of the null-tests proposed are done at map level with sometime compression of their
+
[[File:Fig_14.png|thumb|center|900px]]
statistical information into an angular power spectrum. However
 
together with full-sky maps it is interesting to have a closer look on some specific sources.
 
I would be important to compare fluxes from both polarized and un-polarized point sources with
 
different radiometers in order to asses possible calibration mis-match and/or polarization leakage issues.
 
Such comparison will also possibly indicate problems related to channel central frequencies.
 
The proposed set of sources would be: M42, Tau A, Cas A and Cyg A. However other H{\sc II} regions
 
like Perseus are valuable. One can compare directly their fluxes from different sky surveys and/or the flux
 
of the difference map and how this is consistent with instrumental noise.
 
  
Which kind of effect is probed with a null-test on a specific time scale? Here it is a simple list. At survey time
+
In this figure we consider the set of odd-even survey differences combining all eight sky surveys covered by LFI. These survey combinations optimize the signal-to-noise ratio and highlight
scale it is possible to underlying any side-lobes effects, while on time scales of full-mission, it is possible to
+
large-scale structures. The nine maps on the left show odd-even survey dfferences for the 2015 release, while the nine maps on the right show the same for the 2018 release. The 2015 data show large residuals in <i>I</i> at 30 and 44 GHz that bias the difference away from zero. This effect is considerably reduced in the 2018 release, as expected from the improvements in the calibration process. The <i>I</i> map at 70 GHz also shows a significant improvement. In the polarization maps, there is a general reduction in the amplitude of structures close to the Galactic plane.
have an indication of calibration problems when observing the sky with the same S/C orientation. Differences
 
at this time scale between horns at the same frequency may also reveal central frequency and beam
 
issues.  
 
  
=== Total Intensity Null Tests ===
+
[[File:Fig_15.png|thumb|center|400px]]
In order to highlight different issues, several time scales and data combinations are considered. The following table
 
is a sort of null-test matrix to be filled with test results. It should be important to try to set a sort
 
of pass/fail criteria for each of the tests and to be prepared to detailed actions in order to avoid
 
and correct any failure of the tests. To assess the results an idea could be to proceed as in the nominal pipeline $i.e.$
 
to compare the angular power spectra of null test maps with a fiducial angular power spectrum of a white noise map.
 
This could be made automatic and, in case the test does not pass then a more thorough investigation could be performed.
 
This will provide an overall indication of the residuals. However structures in the residual are important as well as the
 
overall average level and visual inspection of the data is therefore fundamental.
 
  
Concerning null-tests on various time scales a comment is in order. At large time scales (i.e. of the order of
+
Finally here we shows pseudo-angular power spectra from the oddeven survey dfferences. There is great improvement in 2018 in removing largescale structures at 30 GHz in <i>TT</i>, <i>EE</i>, and somewhat in <i>BB</i>, and also in <i>TT</i> at 44 GHz.
a survey or more) it is clear that the basic data set will be made of the single survey maps at  
 
radiometer/horn/frequency level that will be properly combined to obtain the null-test under consideration.
 
For example at 6 months time scale we will analysis maps of the difference between different surveys
 
for the radiometer/horn/frequency under test. On the other hand at 12 months time scale we will combine
 
surveys 1 and 2 together to be compared with the same combination for surveys 3 and 4.
 
At full-mission time scale, the analysis it is not always possible e.g. at radiometer level we have only one
 
full-mission data set. However it would be interesting to combine odd surveys together and compare them
 
with even surveys again combined together.
 
On shorter time scales (i.e. less than a survey) the data products to be considered are different and
 
will be the output of the jack-knives code when different time scales are considered: the usual half-ring
 
JK on pointing period time scale and the new, if possible, jack-knives on 1 minute time scale.
 
Therefore null-tests will use both surveys/full-mission maps as well as tailored jack-knives maps.
 
  
The following table reports our total intensity null-tests matrix with a $\checkmark$ where tests are possible.
 
{| border="1" cellpadding = "5" cellspacing = "0" align = "centre"
 
|-
 
! Data Set
 
! 1minute
 
! 1 hour
 
! Survey
 
! Full Mission
 
|-
 
| Radiometer (M/S) || $\checkmark$ || $\checkmark$ || $\checkmark$ || $\checkmark$
 
|-
 
| Horn (M+S) || $\checkmark$ || $\checkmark$ || $\checkmark$ || $\checkmark$
 
|-
 
| Horn Pair$^1$ || || || $\checkmark$ || $\checkmark$
 
|-
 
| Frequency || $\checkmark$ || $\checkmark$ || $\checkmark$ || $\checkmark$
 
|-
 
| Cross-Frequency ||  || || $\checkmark$ || $\checkmark$
 
|}
 
$^1$ this is (M+S)/2 and differences are between couple of horns (e.g. (28M+28S)/2- (27M+27S)/2)
 
  
=== Polarisation Null Tests ===
+
===Intra-frequency consistency check===
The same arguments applies also for polarization analysis with only some differences regarding the possible
+
We have tested the consistency between 30, 44, and 70GHz maps by comparing the power spectra in the multipole range around the first acoustic peak. In order to do so, we have removed the estimated contribution from unresolved point source from the spectra. We have then built scatter plots for the three frequency pairs, i.e., 70GHz versus 30 GHz, 70GHz versus 44GHz, and 44GHz versus 30GHz, and performed a linear fit, accounting for errors on both axes.
combination producing polarized data. Radiometer will not be available, instead of sum between M and S radiometer we will
+
The results reported below show that the three power spectra are consistent within the errors. Moreover, note that the current error budget does not account for foreground removal, calibration, and window function uncertainties. Hence, the observed agreement between spectra at different frequencies can be considered to be even more satisfactory.
consider their difference.
 
  
{| border="1" cellpadding = "5" cellspacing = "0" align = "centre"
+
[[File:Fig_21.png|thumb|center|1200px]]
|-
 
! Data Set
 
! 1minute
 
! 1 hour
 
! Survey
 
! Full Mission
 
|-
 
| Horn (M-S) || $\checkmark$ || $\checkmark$ || $\checkmark$ || $\checkmark$
 
|-
 
| Horn Pair$^1$ || || || $\checkmark$ || $\checkmark$
 
|-
 
| Frequency || $\checkmark$ || $\checkmark$ || $\checkmark$ || $\checkmark$
 
|-
 
| Cross-Frequency ||  || || $\checkmark$ || $\checkmark$
 
|}
 
$^1$ this is difference between couple of horns (e.g. (28M-28S)/2- (27M-27S)/2)
 
  
=== Practical Considerations ===
 
For practical purposed and visual inspection of the null-tests results it would be useful to produce results smoothed at $3^\circ$ (and at $10^\circ$ for highlight larger angular scales) for
 
all the total intensity maps. For polarization, as we already did several times when comparing to $WMAP$ data,
 
a downgrade of the product at $N_{\rm side}=128$ would be useful to highlight large scale residuals. These considerations are
 
free to evolve according to our needs.
 
  
Due to large possibilities and number of data sets to be considered, it would be desirable to have sort of automatic tools that
+
===70 GHz internal consistency check===
ingest two, or more, inputs maps and produce difference map(s) and corresponding angular power spectrum(spectra). This
+
We use the Hausman test {{BibCite|polenta_CrossSpectra}} to assess the consistency of auto- and cross-spectral estimates at 70 GHz. We specifically define the statistic:
has been implemented using Python language and interacting directly with FITS files of a specific data release. The code is
 
parallel and can run both at NERSC and at DPC producing consistent results. In addition for each null-tests performed a JSON
 
DB file is produced in which main test informations are stored together with interesting computed quantities like mean, standard deviation of the residual maps. Beside JSON files also GIF images of the null-test are produced. Such JSON and GIF files are used to create (both with Python again and with Scheme) a report in form of an HTML page from the LFI Wiki.
 
  
Together with images, power spectra of the residual are also produced and compared with the expected level of white noise
+
:<math>
derived from the half-ring jack-knifes. With these quantities are combined to produce a sort of $\chi^2$. This gives an indication of the deviation of the residuals with respect to the white noise level. Of course underlying signal does not posses a Gaussian statistic and therefore with non-Gaussian data, the $\chi^2$ tests is less meaningful. However this gives an hint on the presence of residuals which in some cases are indeed expected: in fact making difference between odd and even survey at horn and frequency level, is a way to show the signature of the external stray-light which, although properly accounted for during the calibration procedure, has not been removed from the data.
+
H_{\ell}=\left(\hat{C_{\ell}}-\tilde{C_{\ell}}\right)/\sqrt{{\rm Var}\left\{ \hat{C_{\ell}}-\tilde{C_{\ell}}\right\} },
+
</math>
 +
 
 +
where <math>\hat{C_{\ell}}</math>  and <math>\tilde{C_{\ell}}</math> represent auto- and
 +
cross-spectra, respectively. In order to combine information from different multipoles into a single quantity, we define
 +
 
 +
:<math>
 +
B_{L}(r)=\frac{1}{\sqrt{L}}\sum_{\ell=2}^{[Lr]}H_{\ell},r\in\left[0,1\right],
 +
</math>
 +
 
 +
where square brackets denote the integer part. The distribution of <i>B<sub>L</sub></i>(<i>r</i>)
 +
converges (in a functional sense) to a Brownian motion process, which can be studied through the statistics
 +
<i>s</i><sub>1</sub>=sup<sub><i>r</i></sub><i>B<sub>L</sub></i>(<i>r</i>),
 +
<i>s</i><sub>2</sub>=sup<sub><i>r</i></sub>|<i>B<sub>L</sub></i>(<i>r</i>)|, and
 +
<i>s</i><sub>3</sub>=&#8747;<sub>0</sub><sup>1</sup><i>B<sub>L</sub></i><sup>2</sup>(<i>r</i>)dr. Using the "FFP10" simulations,
 +
we derive empirical distributions for all the three test statistics and compare with results obtained from Planck data. We find that the Hausman test shows no statistically significant inconsistencies between the two spectral
 +
estimates.
 +
 
 +
[[File:Fig_23.png|thumb|center|1200px|]]
 +
 
 +
<!--
 
== Data Release Results ==
 
== Data Release Results ==
  
 
=== Impact on cosmology ===
 
=== Impact on cosmology ===
 +
-->
 +
 +
== References ==
 +
 +
<References />
 +
  
[[Category:Data processing|0056]]
+
[[Category:LFI data processing|006]]

Latest revision as of 11:09, 6 July 2018

Overview[edit]

Data validation is critical at each step of the analysis pipeline. Much of the LFI data validation is based on null tests. Here we present some examples from the current release, with comments on relevant time scales and sensitivity to various systematics. In the 2018 release in addition we perform many test to verify the differences between this and previous release (see Planck-2020-A2[1]).

Null tests approach[edit]

Null tests at map level are performed routinely, whenever changes are made to the mapmaking pipeline. These include differences at survey, year, 2-year, half- mission and half-ring levels, for single detectors, horns, horn pairs and full frequency complements. Where possible, map differences are generated in I, Q and U. For this release, we use the Full Focal Plane 10 (FFP10) simulations for comparison. We can use FFP10 noise simulations, identical to the data in terms of sky sampling and with matching time domain noise characteristics, to make statistical arguments about the likelihood of the noise observed in the actual data nulls. In general null tests are performed to highlight possible issues in the data related to instrumental systematic effecst not properly accounted for within the processing pipeline, or related to known changes in the operational conditions (e.g., switch-over of the sorption coolers), or related to intrinsic instrument properties coupled with the sky signal, such as stray light contamination. Such null-tests can be performed by using data on different time scales ranging from 1 minute to 1 year of observations, at different unit levels (radiometer, horn, horn-pair), within frequency and cross-frequency, both in total intensity, and, when applicable, in polarization.

Sample Null Maps[edit]

Fig 13.png

This figure shows difefrences between 2018 and 1015 frequenncy maps in I, Q and U. Large scale differences between the two set of maps are mainly due to changes in the calibration procedure.

Fig 14.png

In this figure we consider the set of odd-even survey differences combining all eight sky surveys covered by LFI. These survey combinations optimize the signal-to-noise ratio and highlight large-scale structures. The nine maps on the left show odd-even survey dfferences for the 2015 release, while the nine maps on the right show the same for the 2018 release. The 2015 data show large residuals in I at 30 and 44 GHz that bias the difference away from zero. This effect is considerably reduced in the 2018 release, as expected from the improvements in the calibration process. The I map at 70 GHz also shows a significant improvement. In the polarization maps, there is a general reduction in the amplitude of structures close to the Galactic plane.

Fig 15.png

Finally here we shows pseudo-angular power spectra from the oddeven survey dfferences. There is great improvement in 2018 in removing largescale structures at 30 GHz in TT, EE, and somewhat in BB, and also in TT at 44 GHz.


Intra-frequency consistency check[edit]

We have tested the consistency between 30, 44, and 70GHz maps by comparing the power spectra in the multipole range around the first acoustic peak. In order to do so, we have removed the estimated contribution from unresolved point source from the spectra. We have then built scatter plots for the three frequency pairs, i.e., 70GHz versus 30 GHz, 70GHz versus 44GHz, and 44GHz versus 30GHz, and performed a linear fit, accounting for errors on both axes. The results reported below show that the three power spectra are consistent within the errors. Moreover, note that the current error budget does not account for foreground removal, calibration, and window function uncertainties. Hence, the observed agreement between spectra at different frequencies can be considered to be even more satisfactory.

Fig 21.png


70 GHz internal consistency check[edit]

We use the Hausman test [2] to assess the consistency of auto- and cross-spectral estimates at 70 GHz. We specifically define the statistic:

[math] H_{\ell}=\left(\hat{C_{\ell}}-\tilde{C_{\ell}}\right)/\sqrt{{\rm Var}\left\{ \hat{C_{\ell}}-\tilde{C_{\ell}}\right\} }, [/math]

where [math]\hat{C_{\ell}}[/math] and [math]\tilde{C_{\ell}}[/math] represent auto- and cross-spectra, respectively. In order to combine information from different multipoles into a single quantity, we define

[math] B_{L}(r)=\frac{1}{\sqrt{L}}\sum_{\ell=2}^{[Lr]}H_{\ell},r\in\left[0,1\right], [/math]

where square brackets denote the integer part. The distribution of BL(r) converges (in a functional sense) to a Brownian motion process, which can be studied through the statistics s1=suprBL(r), s2=supr|BL(r)|, and s3=∫01BL2(r)dr. Using the "FFP10" simulations, we derive empirical distributions for all the three test statistics and compare with results obtained from Planck data. We find that the Hausman test shows no statistically significant inconsistencies between the two spectral estimates.

Fig 23.png


References[edit]

  1. Planck 2018 results. II. Low Frequency Instrument data processing, Planck Collaboration, 2020, A&A, 641, A2.
  2. Unbiased estimation of an angular power spectrum, G. Polenta, D. Marinucci, A. Balbi, P. de Bernardis, E. Hivon, S. Masi, P. Natoli, N. Vittorio, J. Cosmology Astropart. Phys., 11, 1, (2005).

(Planck) Low Frequency Instrument