Summary of LFI data characteristics
The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper Planck-2013-II[1]Planck-2015-A03[2].
Parameter | 30 GHz | 44 GHz | 70 GHz |
---|---|---|---|
Center frequency [GHz] | 28.4 | 44.1 | 70.4 |
Scanning beam FWHM [arcmin] | 33.10 | 27.94 | 13.08 |
Scanning beam ellipticity | 1.37 | 1.25 | 1.27 |
Effective beam FWHM [arcmin] | 32.29 | 27.00 | 13.21 |
White noise level in map | [ K ]*TBD | *TBD | *TBD |
White noise level in timelines | [ K ]148.1 | 174.2 | 152.0 |
f | [mHz]114.1 | 52.4 | 19.7 |
1/ | slope-0.92 | -0.88 | -1.20 |
Overall calibration uncertainty | [%]0.35 | 0.26 | 0.29 |
Systematic effects uncertainty in Stokes | [ K ]0.88 | 1.97 | 1.87 |
Systematic effects uncertainty in Stokes | [ K ]1.11 | 1.14 | 2.25 |
Systematic effects uncertainty in Stokes | [ K ]0.95 | 1.29 | 2.22 |
Determined by fitting Jupiter observations directly in the timelines.
Planck-2013-XXVIII[3]Planck-2015-A35[4].
Calculated from the main beam solid angle of the effective beam, . These values are used in the source extraction pipelineWhite noise per pixel computed from half-ring difference maps. These values are within 1% of the white noise sensitivity computed directly on the timelines, taking into account the actual integration time represented in the maps.
Values derived from fitting noise spectra.
Planck-2013-V[5]Planck-2015-A05[6].
Sum of the error on the estimation of the calibration constant (0.25 %) and the square root of the squared sum of the following errors: beam uncertainty; sidelobe convolution effect; and unknown systematics as measured from the power spectrum at (seePlanck-2013-III[7]Planck-2015-A03[2].
Peak-to-peak difference between 99% and 1% quantities in the pixel value distributions from simulated maps (seeReferences[edit]
- ↑ Planck 2013 results. II. Low Frequency Instrument data processing, Planck Collaboration, 2014, A&A, 571, A2.
- ↑ 2.02.1 Planck 2015 results. II. LFI processing, Planck Collaboration, 2016, A&A, 594, A2.
- ↑ Planck 2013 results. XXVIII. The Planck Catalogue of Compact Sources, Planck Collaboration, 2014, A&A, 571, A28.
- ↑ Planck 2015 results. XXVI. The second Planck catalogue of compact sources, Planck Collaboration, 2016, A&A, 594, A26.
- ↑ Planck 2013 results. V. LFI Calibration, Planck Collaboration, 2014, A&A, 571, A5.
- ↑ Planck 2015 results. IV. LFI beams and window functions, Planck Collaboration, 2016, A&A, 594, A4.
- ↑ Planck 2013 results. III. Low Frequency Instrument systematic uncertainties, Planck Collaboration, 2014, A&A, 571, A3.
(Planck) Low Frequency Instrument
Full-Width-at-Half-Maximum
Cosmic Microwave background
To be defined / determined