Difference between revisions of "Scanning Beams"

From Planck Legacy Archive Wiki
Jump to: navigation, search
(Created page with " ===Note on the file format=== The stokes map files consist in four columns containing the stokes parameters for each sample, encoding all the information on the field inten...")
 
(Note on the file format)
Line 4: Line 4:
  
 
The stokes map files consist in four columns containing the stokes parameters for each sample, encoding all the information on the field intensity and polarization properties.  
 
The stokes map files consist in four columns containing the stokes parameters for each sample, encoding all the information on the field intensity and polarization properties.  
The columns are called ``Beamdata'' , ``BeamdataQ'', ``BeamdataU'' and ``BeamdataV'', containing respectively the <math>I</math> <math>Q</math>,<math>U</math> and <math>V</math> Stokes parameters.
+
The columns are called "Beamdata" , "BeamdataQ", "BeamdataU" and "BeamdataV", containing respectively the <math>I</math> <math>Q</math>,<math>U</math> and <math>V</math> Stokes parameters.
 
There are differences in the data format between the Main Beam and the near and far Sidelobes.
 
There are differences in the data format between the Main Beam and the near and far Sidelobes.
 
Main Beams are sampled with a grid map on the tangent space. The dimension of the grid is given by the keywords ``Nx'' and ``Ny'', representing the number of columns and rows of the grid map .  
 
Main Beams are sampled with a grid map on the tangent space. The dimension of the grid is given by the keywords ``Nx'' and ``Ny'', representing the number of columns and rows of the grid map .  
 
The four stokes columns contain the succession of the <math>Nx \times Ny</math> samples of the map.
 
The four stokes columns contain the succession of the <math>Nx \times Ny</math> samples of the map.
 
Sidelobes are sampled on the sphere. The resolution in <math>\theta</math> and <math>\phi</math> is given by the  keywords `Ntheta'' and  ``Nphi''. The columns contain the succession of <math>Nphi</math> Stokes parameters for each $\theta$.
 
Sidelobes are sampled on the sphere. The resolution in <math>\theta</math> and <math>\phi</math> is given by the  keywords `Ntheta'' and  ``Nphi''. The columns contain the succession of <math>Nphi</math> Stokes parameters for each $\theta$.

Revision as of 18:24, 16 December 2014


Note on the file format

The stokes map files consist in four columns containing the stokes parameters for each sample, encoding all the information on the field intensity and polarization properties. The columns are called "Beamdata" , "BeamdataQ", "BeamdataU" and "BeamdataV", containing respectively the [math]I[/math] [math]Q[/math],[math]U[/math] and [math]V[/math] Stokes parameters. There are differences in the data format between the Main Beam and the near and far Sidelobes. Main Beams are sampled with a grid map on the tangent space. The dimension of the grid is given by the keywords ``Nx and ``Ny, representing the number of columns and rows of the grid map . The four stokes columns contain the succession of the [math]Nx \times Ny[/math] samples of the map. Sidelobes are sampled on the sphere. The resolution in [math]\theta[/math] and [math]\phi[/math] is given by the keywords `Ntheta and ``Nphi. The columns contain the succession of [math]Nphi[/math] Stokes parameters for each $\theta$.