Difference between revisions of "HFI reference bolometer"
(One intermediate revision by the same user not shown) | |||
Line 6: | Line 6: | ||
<div "id=tab:BREF"></div> | <div "id=tab:BREF"></div> | ||
|- | |- | ||
− | | Band [GHz] || No. Interfer. || No. Spec. || MPD [cm] || ILS FWHM [cm<sup>-1</sup>] || | + | | Band [GHz] || No. Interfer. || No. Spec. || MPD [cm] || ILS FWHM [cm<sup>-1</sup>] || Avg. S/N |
|- | |- | ||
| 100 || 164 || 164 || 29.644698 || 0.020357772 || 11.478057 | | 100 || 164 || 164 || 29.644698 || 0.020357772 || 11.478057 | ||
Line 43: | Line 43: | ||
<small>Reference bolometer spectra (top) and S/N (bottom) for each of the HFI bands (vertical dashed lines represent band edges).</small> | <small>Reference bolometer spectra (top) and S/N (bottom) for each of the HFI bands (vertical dashed lines represent band edges).</small> | ||
</center> | </center> | ||
+ | |||
+ | <br> | ||
<center> | <center> | ||
[[Image:SNall_sm.png|thumb|500px|center|Approximate S/N ratio for the individual HFI detector spectra and the reference bolometer spectra.]] | [[Image:SNall_sm.png|thumb|500px|center|Approximate S/N ratio for the individual HFI detector spectra and the reference bolometer spectra.]] | ||
+ | |||
+ | <br> | ||
</center> | </center> | ||
[[Category:HFI design, qualification and performance|008]] | [[Category:HFI design, qualification and performance|008]] |
Latest revision as of 07:48, 10 December 2014
This sections provides information on the reference bolometer interferograms and spectra used in determining the relative spectral response functions for the Planck HFI detectors and frequency bands.
Band [GHz] | No. Interfer. | No. Spec. | MPD [cm] | ILS FWHM [cm-1] | Avg. S/N |
100 | 164 | 164 | 29.644698 | 0.020357772 | 11.478057 |
143 | 164 | 164 | 29.644698 | 0.020357772 | 37.361317 |
217 | 164 | 164 | 29.644698 | 0.020357772 | 126.14280 |
353 | 24 | 24 | 29.652306 | 0.020352549 | 136.06159 |
545 | 24 | 24 | 29.652306 | 0.020352549 | 314.58093 |
857 | 24 | 24 | 29.652306 | 0.020352549 | 388.23050 |
Reference bolometer spectra and S/N.
Reference bolometer spectra (top) and S/N (bottom) for each of the HFI bands (vertical dashed lines represent band edges).
(Planck) High Frequency Instrument
Instrument Line Shape
Full-Width-at-Half-Maximum