Difference between revisions of "HFI reference bolometer"
Line 1: | Line 1: | ||
+ | This sections provides information on the reference bolometer interferograms and spectra used in determining the relative spectral response functions for the Planck HFI detectors and frequency bands. | ||
+ | |||
<center> | <center> | ||
{| border=1 | {| border=1 |
Revision as of 18:45, 25 November 2014
This sections provides information on the reference bolometer interferograms and spectra used in determining the relative spectral response functions for the Planck HFI detectors and frequency bands.
Band (GHz) | # Ifgm. | # Spec. | MPD (cm) | ILS (cm ) | avg. S/N |
100 | 164 | 164 | 29.644698 | 0.020357772 | 11.478057 |
143 | 164 | 164 | 29.644698 | 0.020357772 | 37.361317 |
217 | 164 | 164 | 29.644698 | 0.020357772 | 126.14280 |
353 | 24 | 24 | 29.652306 | 0.020352549 | 136.06159 |
545 | 24 | 24 | 29.652306 | 0.020352549 | 314.58093 |
857 | 24 | 24 | 29.652306 | 0.020352549 | 388.23050 |
Reference bolometer spectra and S/N.
Reference bolometer spectra (top) and S/N (bottom) for each of the HFI bands (vertical bars represent band edges).
(Planck) High Frequency Instrument
Instrument Line Shape
Full-Width-at-Half-Maximum