Difference between revisions of "Beams LFI"

From Planck PLA 2015 Wiki
Jump to: navigation, search
(Main Beams and Focal Plane calibration)
(Main Beams and Focal Plane calibration)
Line 49: Line 49:
 
$\psi_{uv}$ and $\psi_{pol}$ are '''not''' derived from measurements but they are extimated form '''optical simulations'''. They are the quantities that represent the polarization direction of each beam, in the following approximation: '''the M- and  S- beams of the same RCA point at the same direction on the sky'''.
 
$\psi_{uv}$ and $\psi_{pol}$ are '''not''' derived from measurements but they are extimated form '''optical simulations'''. They are the quantities that represent the polarization direction of each beam, in the following approximation: '''the M- and  S- beams of the same RCA point at the same direction on the sky'''.
  
Main beams shape is characterised by 2 method:  
+
The main beams are characterised by 2 method:  
 +
 
 +
* elliptical (or bivariate) gaussian fit as in <cite>#[planck2011-1-6]</cite> with modification explained in <cite>#[planck2013-p02d]</cite>. This method is used to determine
 +
**the beam centre
 +
**the average full width half maximum defined as $\sqrt{FWHM_{max}\cdot FWHM_{min}}$
 +
the beam ellipticity defined as , the ti
  
* elliptical (or bivariate) gaussian fit as explained in <cite>#[planck2011-1-6]</cite>.
 
 
* Electromagnetic simulation (using GRASP Physical Optics code) by appropriately tuning the Radio Frequency Flight Model (RFFM) <cite>#tauber2010b</cite>.
 
* Electromagnetic simulation (using GRASP Physical Optics code) by appropriately tuning the Radio Frequency Flight Model (RFFM) <cite>#tauber2010b</cite>.
  

Revision as of 14:20, 12 March 2013

Wish List[edit]

list of information to be inserted in the explanatory supplements

- Description of LFI FOV.

- Description of various telescope models as reported in the beam paper.

- Format of beam data

- Definition of various coordinate frames for beams

Overview[edit]

LFI is observing the sky with 11 pairs of beams associated with the 22 pseudo-correlation radiometers. Each beam of the radiometer pair (Radiometer Chain Assembly - RCA) is named as LFIXXM or LFIXXS. XX is the RCA number ranging from 18 to 28; M and S are the two polarization namely main-arm and side-arm of the Orthomode transducers #darcangelo2009b (see also LFI naming convention).

Figure 1. A sketch of the Planck LFI field of view in the (u,v) plane is shown. The polarization direction on the sky are highlighted by the colored arrows. The M-polarization is shown in green and the S-polarization in red. Main beam shapes are shown for completness and they are not representative of flight beams.



Main Beams and Focal Plane calibration[edit]

As the focal plane calibration we refer to the determination of the beam pointing parameters in the nominal Line of Sight (LOS) frame through main beam measurments using Jupiter transits. the parametes that characterise the beam pointing are the following:

  • THETA_UV ($\theta_{uv}$)
  • PHI_UV ($\phi_{uv}$)

They are calculated starting from u,v coordinates derived form the beam reconstruction algorithm as

$\theta_{uv} = \arcsin(u^2+v^2)$

$\phi_{uv} = \arctan(v/u)$

Two additional angles are used to characterize the beams in the RIMO:

  • PSI_UV ($\psi_{uv}$)
  • PSI_POL ($\psi_{pol}$)

$\psi_{uv}$ and $\psi_{pol}$ are not derived from measurements but they are extimated form optical simulations. They are the quantities that represent the polarization direction of each beam, in the following approximation: the M- and S- beams of the same RCA point at the same direction on the sky.

The main beams are characterised by 2 method:

  • elliptical (or bivariate) gaussian fit as in #[planck2011-1-6] with modification explained in #[planck2013-p02d]. This method is used to determine
    • the beam centre
    • the average full width half maximum defined as $\sqrt{FWHM_{max}\cdot FWHM_{min}}$

the beam ellipticity defined as , the ti

  • Electromagnetic simulation (using GRASP Physical Optics code) by appropriately tuning the Radio Frequency Flight Model (RFFM) #tauber2010b.

Effective beams[edit]

TBW

Window Functions[edit]

TBW

Sidelobes[edit]

There is no direct measurements of sidelobes for LFI. The sidelobe pattern is estimated by simulations taking into account the geometry of the telescope and the satellite structure. In figure

References[edit]

<biblio force=false>

  1. References

</biblio>

(Planck) Low Frequency Instrument

Field-Of-View

LFI Radiometer Chain Assembly

[LFI meaning]: absolute calibration refers to the 0th order calibration for each channel, 1 single number, while the relative calibration refers to the component of the calibration that varies pointing period by pointing period.

Line Of Sight

reduced IMO

Full-Width-at-Half-Maximum