Difference between revisions of "Summary LFI"

From Planck PLA 2015 Wiki
Jump to: navigation, search
Line 8: Line 8:
 
<math>^{ \rm a \, }</math> FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. <math>\hspace{480mm} </math>
 
<math>^{ \rm a \, }</math> FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. <math>\hspace{480mm} </math>
 
<math>^{ \rm b \, }</math> FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline <cite>#planck2013-p05</cite> {{P2013|28}}.
 
<math>^{ \rm b \, }</math> FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline <cite>#planck2013-p05</cite> {{P2013|28}}.
<math>{\hspace{70mm}}
+
<math>{\hspace{70mm}}</math>
 
<math>^{ \rm c \, }</math> White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.
 
<math>^{ \rm c \, }</math> White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.
 
]]  
 
]]  

Revision as of 16:39, 23 May 2014

The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper #planck2013-p02 Planck-2013-II .


Table 1. Summary of the LFI performance parameters

[math]^{ \rm a \, }[/math] FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. [math]\hspace{480mm} [/math] [math]^{ \rm b \, }[/math] FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline #planck2013-p05 Planck-2013-XXVIII . [math]{\hspace{70mm}}[/math] [math]^{ \rm c \, }[/math] White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.


References[edit]

<biblio force=false>

  1. References

</biblio>

(Planck) Low Frequency Instrument

Full-Width-at-Half-Maximum