Difference between revisions of "BibTestLM"
(Created page with '{{PPreLaunch|10||link=and we get a link here <cite>#dupac2005,#hanson2009</cite>}} but it looks a bit odd. <biblio force=false> #References </biblio>') |
|||
Line 1: | Line 1: | ||
+ | |||
+ | |||
+ | <nowiki> ; Determine a powerlaw colour correction for 100 GHz detectors. | ||
+ | hfi_100_cc = hfi_color_correction(BP_INFO=hfi_bp, '100', hfibolo_100_cc, $ | ||
+ | </nowiki> | ||
+ | <tt> /POWERLAW, ALPHA=2.0, ABP=hfi_avg, AVG_CC=AVG_100_cc)</tt><br /> | ||
+ | <tt>help, hfibolo_100_cc, /struct ; Print info about the detector output.</tt><br /> | ||
+ | <tt> ; Determine a modified blackbody colour correction for Beta = 1.8 and T = 18 K.</tt><br /> | ||
+ | <tt>hfi_545_cc = hfi_color_correction(BP_INFO=hfi_bp, '545', hfibolo_545_cc, /MODBLACKBODY, $</tt><br /> | ||
+ | <tt> TBD = 18d, BETABD = 1.8d, ABP=hfi_avg, CH_CC=CH_545_CC, AVG_CC=AVG_545_CC)</tt><br /> | ||
+ | <tt> print, hfibolo_545_cc.BOLONAME</tt><br /> | ||
+ | <tt> print, hfibolo_545_cc.CC</tt> | ||
+ | * Note that 545-3 is set to <math>-10^9</math> as this detector is not included in flight data products due to excessive noise. | ||
+ | <tt> ; Try to use a user-input spectrum</tt><br /> | ||
+ | <tt>nu = (hfi_avg[5].freq) ; in Hz</tt><br /> | ||
+ | <tt>Inu = COS((hfi_avg[5].trans)) ; some arb. profile</tt><br /> | ||
+ | <tt>hfi_857_cc = hfi_color_correction(BP_INFO=hfi_bp, '857', nu, Inu, hfibolo_857_cc, $</tt><br /> | ||
+ | <tt> ABP=hfi_avg, CH_CC=CH_857_CC, AVG_CC=AVG_857_CC)</tt><br /> | ||
+ | <tt>print, hfibolo_857_cc.BOLONAME</tt><br /> | ||
+ | <tt> print, hfibolo_857_cc.CC</tt> | ||
+ | |||
+ | <tt> ; Try to use another user-input spectrum</tt><br /> | ||
+ | <tt>nu = (hfi_avg[5].freq) ; in Hz</tt><br /> | ||
+ | <tt>Inu = LOG((hfi_avg[5].trans)) ; some arb. profile</tt><br /> | ||
+ | <tt>hfi_857_cc = hfi_color_correction(BP_INFO=hfi_bp, '857', nu, Inu, hfibolo_857_cc, $</tt><br /> | ||
+ | <tt> ABP=hfi_avg, CH_CC=CH_857_CC, AVG_CC=AVG_857_CC)</tt><br /> | ||
+ | <tt>print, hfibolo_857_cc.BOLONAME</tt><br /> | ||
+ | <tt> print, hfibolo_857_cc.CC</tt> | ||
+ | |||
+ | |||
{{PPreLaunch|10||link=and we get a link here <cite>#dupac2005,#hanson2009</cite>}} but it looks a bit odd. | {{PPreLaunch|10||link=and we get a link here <cite>#dupac2005,#hanson2009</cite>}} but it looks a bit odd. | ||
Revision as of 12:58, 30 January 2013
; Determine a powerlaw colour correction for 100 GHz detectors.
hfi_100_cc = hfi_color_correction(BP_INFO=hfi_bp, '100', hfibolo_100_cc, $
/POWERLAW, ALPHA=2.0, ABP=hfi_avg, AVG_CC=AVG_100_cc)
help, hfibolo_100_cc, /struct ; Print info about the detector output.
; Determine a modified blackbody colour correction for Beta = 1.8 and T = 18 K.
hfi_545_cc = hfi_color_correction(BP_INFO=hfi_bp, '545', hfibolo_545_cc, /MODBLACKBODY, $
TBD = 18d, BETABD = 1.8d, ABP=hfi_avg, CH_CC=CH_545_CC, AVG_CC=AVG_545_CC)
print, hfibolo_545_cc.BOLONAME
print, hfibolo_545_cc.CC
- Note that 545-3 is set to as this detector is not included in flight data products due to excessive noise.
; Try to use a user-input spectrum
nu = (hfi_avg[5].freq) ; in Hz
Inu = COS((hfi_avg[5].trans)) ; some arb. profile
hfi_857_cc = hfi_color_correction(BP_INFO=hfi_bp, '857', nu, Inu, hfibolo_857_cc, $
ABP=hfi_avg, CH_CC=CH_857_CC, AVG_CC=AVG_857_CC)
print, hfibolo_857_cc.BOLONAME
print, hfibolo_857_cc.CC
; Try to use another user-input spectrum
nu = (hfi_avg[5].freq) ; in Hz
Inu = LOG((hfi_avg[5].trans)) ; some arb. profile
hfi_857_cc = hfi_color_correction(BP_INFO=hfi_bp, '857', nu, Inu, hfibolo_857_cc, $
ABP=hfi_avg, CH_CC=CH_857_CC, AVG_CC=AVG_857_CC)
print, hfibolo_857_cc.BOLONAME
print, hfibolo_857_cc.CC
and we get a link here #dupac2005,#hanson2009 but it looks a bit odd.
<biblio force=false>
</biblio>
To be defined / determined