The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper {{PlanckPapers|planck2013-p02}}.
 
The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper {{PlanckPapers|planck2013-p02}}.
 
=== Summary of LFI Performance ===
 
 
A summary of the LFI performance parameters is given in the table 3 below.
 
  
 
{| border="1" cellspacing="0" cellpadding="2" align="center"
 
{| border="1" cellspacing="0" cellpadding="2" align="center"
|+ '''Table 3. LFI performance parameters'''
+
|+ '''Table 1. LFI performance parameters'''
 
|-
 
|-
 
!scope="col"| Parameter  
 
!scope="col"| Parameter  
Line 65: Line 61:
 
|-
 
|-
 
|}
 
|}
 
 
  
 
<math>^{\rm a}</math> Determined by fitting Jupiter observations directly in the timelines.
 
<math>^{\rm a}</math> Determined by fitting Jupiter observations directly in the timelines.
Line 81: Line 75:
 
distributions from simulated maps (see {{PlanckPapers|planck2013-p02a}}.
 
distributions from simulated maps (see {{PlanckPapers|planck2013-p02a}}.
  
<center>
 
'''Table 1. Summary of the LFI performance parameters'''
 
[[File:tab_perf2.jpg|thumb|center|600px|
 
<math>^{ \rm a \, }</math> FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. <math>\hspace{480mm} </math>
 
<math>^{ \rm b \, }</math> FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline {{PlanckPapers|planck2013-p05}}.
 
<math>{\hspace{35mm}}</math>
 
<math>^{ \rm c \, }</math> White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.
 
]]
 
</center>
 
  
 
<!--
 
<!--

Revision as of 12:09, 16 December 2014

The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper Planck-2013-II[1].

Table 1. LFI performance parameters
Parameter 30 GHz 44 GHz 70 GHz
Center frequency [GHz] 28.4 44.1 70.4
Scanning beam FWHM[math]^{\rm a}[/math] [arcmin] 33.10 27.94 13.08
Scanning beam ellipticity[math]^{\rm a}[/math] 1.37 1.25 1.27
Effective beam FWHM[math]^{\rm b}[/math] [arcmin] 32.29 27.00 13.21
White noise level in map[math]^{\rm c}[/math] [[math]\mu[/math]K[math]_{CMB}[/math]] *TBD *TBD *TBD
White noise level in timelines[math]^{\rm d}[/math] [[math]\mu[/math]K[math]_{CMB} \;s^{1/2}[/math]] 148.1 174.2 152.0
f[math]_{\rm knee}^{\rm d}[/math] [mHz] 114.1 52.4 19.7
1/[math]f[/math] slope[math]^{\rm d}[/math] -0.92 -0.88 -1.20
Overall calibration uncertainty[math]^{\rm e}[/math] [%] *TBD *TBD *TBD
Systematic effects uncertainty[math]^{\rm f}[/math] [[math]\mu[/math]K[math]_{CMB}[/math]] *TBD *TBD *TBD

[math]^{\rm a}[/math] Determined by fitting Jupiter observations directly in the timelines.

[math]^{\rm b}[/math] Calculated from the main beam solid angle of the effective beam, [math]\Omega_{\rm eff} = \hbox{mean}(\Omega)[/math]. These values are used in the source extraction pipeline Planck-2013-XXVIII[2].

[math]^{\rm c}[/math] White noise per pixel computed from half-ring difference maps. These values are within 1% of the white noise sensitivity computed directly on the timelines, taking into account the actual integration time represented in the maps.

[math]^{\rm d}[/math] Values derived from fitting noise spectra.

[math]^{\rm e}[/math] Sum of the error on the estimation of the calibration constant (0.25 %) and the square root of the squared sum of the following errors: beam uncertainty; sidelobe convolution effect; and unknown systematics as measured from the power spectrum at [math]50 \lt \ell \lt 250 [/math] (see Planck-2013-V[3].

[math]^{\rm f}[/math] Peak-to-peak difference between 99% and 1% quantities in the pixel value distributions from simulated maps (see Planck-2013-III[4].


References[edit]

  1. Planck 2013 results. II. Low Frequency Instrument data processing, Planck Collaboration, 2014, A&A, 571, A2
  2. Planck 2013 results. XXVIII. The Planck Catalogue of Compact Sources, Planck Collaboration, 2014, A&A, 571, A28
  3. Planck 2013 results. V. LFI Calibration, Planck Collaboration, 2014, A&A, 571, A5
  4. Planck 2013 results. III. Low Frequency Instrument systematic uncertainties, Planck Collaboration, 2014, A&A, 571, A3

(Planck) Low Frequency Instrument

Full-Width-at-Half-Maximum

Cosmic Microwave background

To be defined / determined