Difference between revisions of "ZodiFreqFits"

From Planck PLA Wiki
Jump to: navigation, search
(Created page with '600px|857 GHz Zodi Fit Results 600px|545 GHz Zodi Fit Results [[File:111110111111111__353__10-0.pn…')
 
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
Fits to the COBE Zodiacal Emission model at each Planck/HFI frequency are encapsulated in the files below.
 +
 
[[File:111110111111111__857__10-0.png|600px|857 GHz Zodi Fit Results]]
 
[[File:111110111111111__857__10-0.png|600px|857 GHz Zodi Fit Results]]
 +
 +
Results of fits at 857 GHz. Data from the first year of observations are shown in white, while data from the second year of observations are shown in gray. Surveys 1 and 3 are shown with circles, while surveys 2 and 4 are shown with squares. The average of the points shown, and the uncertainties are representated with the horizontal gray band, and where appropriate, a dotted line is used to mark the `zero' level.
 +
 +
For 545 GHz:
 
[[File:111110111111111__545__10-0.png|600px|545 GHz Zodi Fit Results]]
 
[[File:111110111111111__545__10-0.png|600px|545 GHz Zodi Fit Results]]
 +
 +
For 353 GHz:
 
[[File:111110111111111__353__10-0.png|600px|353 GHz Zodi Fit Results]]
 
[[File:111110111111111__353__10-0.png|600px|353 GHz Zodi Fit Results]]
 +
 +
For 217 GHz:
 
[[File:111110111111111__217__10-0.png|600px|217 GHz Zodi Fit Results]]
 
[[File:111110111111111__217__10-0.png|600px|217 GHz Zodi Fit Results]]
 +
 +
For 143 GHz:
 
[[File:111110111111111__143__10-0.png|600px|143 GHz Zodi Fit Results]]
 
[[File:111110111111111__143__10-0.png|600px|143 GHz Zodi Fit Results]]
 +
 +
For 100 GHz:
 
[[File:111110111111111__100__10-0.png|600px|100 GHz Zodi Fit Results]]
 
[[File:111110111111111__100__10-0.png|600px|100 GHz Zodi Fit Results]]

Latest revision as of 16:13, 20 February 2013

Fits to the COBE Zodiacal Emission model at each Planck/HFI frequency are encapsulated in the files below.

857 GHz Zodi Fit Results

Results of fits at 857 GHz. Data from the first year of observations are shown in white, while data from the second year of observations are shown in gray. Surveys 1 and 3 are shown with circles, while surveys 2 and 4 are shown with squares. The average of the points shown, and the uncertainties are representated with the horizontal gray band, and where appropriate, a dotted line is used to mark the `zero' level.

For 545 GHz: 545 GHz Zodi Fit Results

For 353 GHz: 353 GHz Zodi Fit Results

For 217 GHz: 217 GHz Zodi Fit Results

For 143 GHz: 143 GHz Zodi Fit Results

For 100 GHz: 100 GHz Zodi Fit Results

(Planck) High Frequency Instrument