DepointingVibrations

From Planck PLA Wiki
Revision as of 11:56, 8 August 2012 by Kganga (talk | contribs)
Jump to: navigation, search

Microphonic noise is a potential concern for bolometric detectors.

We check for microphonic contamination in each detector by coadding 15000 rings, each referenced in time around the first thruster firing before the ring. The results are shown for each frequency set in the six following figures.

border100 GHz Ring Stack


143 GHz Ring Stack


217 GHz Ring Stack


353 GHz Ring Stack


545 GHz Ring Stack


857 GHz Ring Stack

Significant signal is seen in many detectors at zero seconds, which is when the first thruster is fired to make a ring change. At 545 GHz, signals are also seen at 120 and 180 seconds, the times of the second and third (or last) thruster firing for each change. As four minutes of data are always flaged after the beginning of any pointing change, none of these effects will be seen in the data.

The 857 GHz signal is dominated by residual Galactic signal.