Difference between revisions of "Summary LFI"

From Planck Legacy Archive Wiki
Jump to: navigation, search
Line 1: Line 1:
 
{{DISPLAYTITLE:Summary of LFI data characteristics}}
 
{{DISPLAYTITLE:Summary of LFI data characteristics}}
The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper {{PlanckPapers|planck2013-p02}} {{P2013|2}}.
+
The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper {{PlanckPapers|planck2013-p02}}.
  
  
Line 7: Line 7:
 
[[File:tab_perf2.jpg|thumb|center|600px|
 
[[File:tab_perf2.jpg|thumb|center|600px|
 
<math>^{ \rm a \, }</math> FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. <math>\hspace{480mm} </math>
 
<math>^{ \rm a \, }</math> FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. <math>\hspace{480mm} </math>
<math>^{ \rm b \, }</math> FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline {{PlanckPapers|planck2013-p05}} {{P2013|28}}.
+
<math>^{ \rm b \, }</math> FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline {{PlanckPapers|planck2013-p05}}.
 
<math>{\hspace{35mm}}</math>
 
<math>{\hspace{35mm}}</math>
 
<math>^{ \rm c \, }</math> White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.
 
<math>^{ \rm c \, }</math> White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.

Revision as of 15:20, 17 July 2014

The LFI performance are summarized in Table 1 below. All the details can be found in the LFI data processing paper Planck-2013-II[1].


Table 1. Summary of the LFI performance parameters

[math]^{ \rm a \, }[/math] FWHM and ellipticity from scanning beam evaluated fitting Jupiter directly in the timelines. [math]\hspace{480mm} [/math] [math]^{ \rm b \, }[/math] FWHM from effective beam estimated from the main beam solid angle of the effective beam. Those are the values used in the source extraction pipeline Planck-2013-XXVIII[2]. [math]{\hspace{35mm}}[/math] [math]^{ \rm c \, }[/math] White noise per pixel computed from half-ring difference maps. Those values are within the 1% with the white noise sensitivity computed directly on the timelines, taking in account the actual mission time minus the manoeuvres and bad-science flagged data.


References[edit]

<biblio force=false>

  1. References

</biblio>

(Planck) Low Frequency Instrument

Full-Width-at-Half-Maximum